Steel Fire Exit Doors

Steel Fire Exit Doors for Safe Emergency Egress

Maxium supplies made-to-measure steel fire exit doors for commercial, industrial and public buildings throughout the UK. Designed to provide fast and straightforward escape during an emergency, our doors can be fitted with panic bars, push pads and other suitable emergency-exit hardware.

Available as single or double doorsets, each steel fire exit door is manufactured to suit the structural opening, expected level of use and required access arrangements. Options include external access, security locking, vision panels, accessible thresholds and durable powder-coated finishes.

These doors are suitable for new developments and the replacement of damaged, outdated or unreliable emergency exits in locations such as warehouses, factories, schools, offices, retail premises and public buildings.

A standard fire exit door is designed to provide emergency egress and does not necessarily require certified fire resistance. Where the project specification requires the doorset to resist fire for a stated period, Maxium can instead supply a separately tested and certified fire-rated doorset.

Steel door frame perspective detail

BS EN 1125 & BS EN 179

Panic and Emergency Exit Hardware
Orange door frame wall section

BS EN 1125

Public or unfamiliar occupants

BS EN 179

staff or familiar occupants

Select escape hardware according to the expected users and building use

GET A FREE QUOTE, TODAY!

Use our quote builder or Call 01279 271192

Damaged, corroded or unreliable fire exit doors can make an emergency escape route difficult to use and leave a building vulnerable to unauthorised access. Maxium supplies made-to-measure replacement steel fire exit doors for commercial, industrial and public buildings.

Each replacement doorset can be manufactured around the existing structural opening and configured for the way the exit is used. This includes selecting appropriate panic hardware, external access, thresholds, locking and finishes.

A replacement may be required where the existing door has:

  • Corrosion or damage to the door leaf or frame
  • Faulty panic bars, push pads or escape hardware
  • Misalignment that prevents reliable opening or closing
  • Damaged hinges, seals, thresholds or locking points
  • Poor weather resistance around an external exit
  • Outdated hardware that no longer suits the building
  • Repeated maintenance problems or unauthorised access

Replacement steel fire exit doors are suitable for warehouses, factories, schools, retail premises, offices, leisure facilities and other buildings requiring dependable emergency egress.

Maxium can provide supply-only or installation options, depending on the project and location. Photographs, approximate dimensions and details of the existing escape hardware will help us identify a suitable replacement.

The correct escape hardware allows occupants to open a steel fire exit door quickly from inside the building without using a key, code or access credential. The appropriate arrangement will depend on how the building is used, the number and familiarity of its occupants, and the requirements identified within its fire-safety strategy. Hardware options can include:
  • Single-point emergency escape push pads
  • Single or multi-point panic bars
  • Hardware for single and double fire exit doors
  • External key access where authorised entry is required
  • Outside access devices and compatible locking
  • Door closers and controlled-closing equipment
  • Hold-open or monitoring options where appropriate
Push pads are commonly used where occupants are familiar with the building and its escape routes. Panic bars provide a larger operating surface and may be more suitable for public buildings and locations where users could be unfamiliar with the exit. External access can also be incorporated without preventing immediate escape from inside. This allows authorised staff to enter through the door while preserving its primary emergency-exit function. Maxium can configure the doorset and escape hardware around the door arrangement, expected users and supplied project specification.

Maxium’s steel fire exit doors are suitable for external escape routes in commercial, industrial and public buildings. Their robust construction provides dependable emergency egress while helping protect less-visible entrances against weather, frequent use and unauthorised access.

Common applications include:

  • Warehouses and distribution centres
  • Factories and manufacturing facilities
  • Retail units and shopping premises
  • Schools, colleges and public buildings
  • Offices and commercial developments
  • Leisure centres and entertainment venues
  • Plant rooms, service areas and rear exits

Doors can be manufactured as single or double configurations and finished in a choice of powder-coated colours. Weather seals, accessible threshold options, vision panels and external access hardware can also be specified around the location and intended use.

Where the exit also needs to provide authorised entry, an external access device can be incorporated without compromising straightforward escape from inside the building.

Each doorset should be selected around the structural opening, expected users, external conditions and the requirements established by the building’s fire-risk assessment or project specification.

Maxium can provide steel fire exit doors on a supply-only basis or as part of a complete installation package, depending on your project requirements and location. Supply only Supply-only doorsets are manufactured to the agreed dimensions and specification, ready for installation by your appointed contractor. Each complete doorset can include the frame, the frame, door leaf, threshold, escape hardware, locking and selected accessories. This option is suitable for contractors and facilities teams with their own experienced installation resources. Fully installed Our installation service can cover the removal of an existing doorset, preparation of the opening, installation of the new steel door and fitting of the specified escape hardware. The installation process can include:
  • Confirmation of dimensions and doorset specification
  • Coordination of delivery and site access
  • Removal of the existing door where agreed
  • Installation of the new door leaf, frame and threshold
  • Fitting of panic bars, push pads and external access hardware
  • Alignment, operational testing and final adjustments
  • Completion checks and project handover
Correct installation is important to ensure the door opens reliably, closes correctly where required and that its escape hardware operates as intended. Installation arrangements will be confirmed around the building, opening and agreed project scope.

Fire exit doors form part of a building’s means of escape and must be suitable for the building, its occupants and the evacuation strategy identified by the fire risk assessment.

For most non-domestic premises in England and Wales, the principal legislation is the Regulatory Reform (Fire Safety) Order 2005. It requires emergency routes and exits to lead as directly as possible to a place of safety and to allow occupants to evacuate as quickly and safely as possible.

Where necessary, emergency doors must open in the direction of escape and be capable of being opened easily and immediately by anyone who may need to use them. Escape routes and exits must also be kept clear and appropriately indicated.

The building’s responsible person must ensure that fire-safety measures, including exit doors and escape hardware, remain in efficient working order and good repair.

Relevant guidance and standards include:

Regulatory Reform (Fire Safety) Order 2005, particularly Articles 14 and 17
Approved Document B: Fire Safety
BS 9999:2017 – Fire safety in the design, management and use of buildings

Regulatory Reform (Fire Safety) Order 2005
Approved Document B

The position, width and opening direction of a fire exit door should be determined as part of the building’s fire strategy and fire risk assessment. Factors include the number of occupants, the intended escape capacity, the type of premises and whether users are familiar with the building.

Exit doors should normally open in the direction of escape, particularly where they serve larger numbers of people or premises where crowd pressure could develop. Government guidance for small non-domestic premises indicates that doors used by more than 60 people should open outwards unless they can be kept open.

The clear opening width must be sufficient for the number and needs of the people expected to use the exit. Thresholds, opening forces, approaches and external landings should also be considered so that the route can be used by people with reduced mobility.

Relevant guidance includes:

  • Approved Document B – means of escape and exit capacity
  • Approved Document M – access to and use of buildings
  • BS 8300-2:2018 – accessible and inclusive building design
  • BS 9999:2017 – fire-safety design and management

Fire exit hardware must allow the door to be released from inside without requiring a key, access code or specialist knowledge. The correct hardware depends primarily on whether occupants are familiar with the building and whether panic conditions could develop.

BS EN 1125:2008 applies to panic exit devices operated by a horizontal push bar or touch bar. These are generally used in public buildings and other premises where occupants may be unfamiliar with the exits or where crowd pressure could occur.

BS EN 179:2008 applies to emergency exit devices operated by a lever handle or push pad. These are normally suited to workplaces and other controlled environments where occupants are familiar with the escape routes and have been instructed in their use.

Where electrically controlled locking or access-control equipment is incorporated, the complete exit system should be designed to release safely under the required emergency conditions. BS EN 13637:2015 covers electrically controlled exit systems used on escape routes.

Relevant standards include:

BS EN 1125:2008 – panic exit devices operated by a horizontal bar
BS EN 179:2008 – emergency exit devices operated by a lever handle or push pad
BS EN 13637:2015 – electrically controlled exit systems

A steel fire exit should be specified and manufactured as a complete doorset, with compatible leaves, frame, hinges, locking points, threshold and escape hardware. Its performance should be appropriate for its location, expected level of use, environmental exposure and security requirements.

BS EN 14351-1:2006+A2:2016 is the product standard covering performance characteristics for windows and external pedestrian doorsets. Depending on the project, relevant declared characteristics may include resistance to wind loading, watertightness, operating forces, impact resistance and thermal performance.

A standard final-exit doorset is not necessarily fire-rated. Where the door forms part of fire or smoke compartmentation, a separately tested and appropriately classified fire-resisting or smoke-control doorset must be specified.

BS EN 16034:2014 covers fire-resisting and smoke-control characteristics for pedestrian doorsets and other door products. The required rating and classification must be established by the building design, fire strategy or fire risk assessment.

Relevant standards include:

BS EN 14351-1:2006+A2:2016 – external pedestrian doorsets
BS EN 16034:2014 – fire-resisting and smoke-control doorsets
BS EN 13501-2 – fire-resistance classification

Correct installation is essential to the reliable operation of a fire exit doorset. The frame must be securely fixed and correctly aligned, with the door leaf, hinges, locking points and escape hardware adjusted so that the door releases immediately and opens freely throughout its intended travel.

The installer should ensure that:

  • The doorset is installed in accordance with the manufacturer’s instructions
  • Panic or emergency hardware is compatible with the doorset
  • The door can be opened from inside without a key or code
  • External access devices do not prevent immediate escape
  • The leaf does not bind against the frame, threshold or floor
  • Double doors release and operate in the intended sequence
  • The threshold and external landing do not create an avoidable hazard
  • The door opens onto a clear route leading to a place of safety
  • All operating and safety checks are completed before handover

Where fire resistance is required, alterations, substitute components or unapproved installation details may invalidate the tested performance of the complete doorset.

There is not one universal British Standard covering the installation of every non-fire-rated steel exit door. Installation should follow the doorset manufacturer’s instructions, the project specification, Approved Document B and the applicable hardware standards.

Fire exit doors and their operating hardware must be maintained in efficient working order and good repair. The appropriate inspection frequency should reflect the building’s fire risk assessment, level of use, environment and the manufacturer’s maintenance instructions.

Routine checks should confirm that:

  • The door and escape route are unobstructed
  • The exit is unlocked whenever the premises are occupied
  • The panic bar, push pad or lever releases the door immediately
  • Hinges, fixings, latches and locking points remain secure
  • The leaf opens freely without dragging or binding
  • The door and frame remain correctly aligned
  • Double-door coordinators and vertical bolts operate correctly
  • External access hardware does not interfere with emergency egress
  • There is no significant corrosion, impact damage or deterioration
  • Signs and emergency lighting remain present and visible
  • The area outside the final exit remains clear
  • Any door closer required by the fire strategy operates correctly

Faults affecting safe escape should be addressed promptly by a competent person. Inspection, testing, maintenance and repairs should be recorded within the premises’ fire-safety logbook.

Government guidance for small non-domestic premises recommends checking daily that exit doors are unlocked, readily openable and unobstructed. More detailed functional inspections should be arranged at suitable intervals determined by risk, usage and manufacturer guidance.

Relevant requirements include:

Article 17 of the Regulatory Reform (Fire Safety) Order 2005
BS 9999:2017 – ongoing fire-safety management
Manufacturer maintenance instructions
BS EN 1125 or BS EN 179, as applicable to the fitted hardware

Fire exit routes and final exits should be clearly identified where occupants may not otherwise be able to locate them quickly. Signs should be positioned consistently along the route and remain visible from relevant approach directions.

BS 5499-4:2013 provides recommendations for escape-route signing using signs conforming to BS EN ISO 7010. Emergency lighting should illuminate escape routes, changes of direction, safety equipment and final exits if normal lighting fails.

Relevant standards include:

  • BS 5499-4:2013 – escape-route signing
  • BS EN ISO 7010 – registered safety signs
  • BS 5266-1:2025 – emergency lighting of premises

British Made With Quality Materials

Free Doorset Specification Advice

Made To Measure For The Perfect Fit

Experienced Sales Team

Project Managed By Our UK Based Team

Nationwide Delivery And Installation

Frequently Asked Questions About Steel Fire Exit Doors

A steel fire exit door is an emergency-exit doorset designed to provide fast and straightforward escape from a building. It is commonly fitted with a panic bar, push pad or other emergency-release hardware that can be operated from inside without a key.
No. A fire exit door provides a means of emergency escape but does not necessarily have certified fire resistance. A fire-rated door is tested as a complete doorset to resist fire for a specified period. Maxium supplies both standard fire exit doors and separate fire-rated doorsets.
Not every steel fire exit door requires a fire rating. This depends on its position within the building, the escape strategy and the project’s fire-safety requirements. Where certified fire resistance is required, a suitable fire-rated doorset should be specified.
A push pad is generally suited to buildings where occupants are familiar with the premises and its escape routes. Panic bars provide a wider operating surface and may be more appropriate in public buildings or locations where occupants could be unfamiliar with the exits. The required hardware should be confirmed within the project specification.
External access can be incorporated using a key-operated or compatible outside access device. This allows authorised entry from outside while preserving immediate, keyless escape from inside the building.
The required opening direction depends on the building, number and type of occupants, escape route and fire-risk assessment. Fire exit doors commonly open in the direction of escape, particularly in public or higher-occupancy buildings, but the correct arrangement should be established for the individual project.
Yes. Maxium supplies made-to-measure replacement fire exit doors for existing openings. Photographs, approximate dimensions, the current door arrangement and details of the escape hardware will help determine the appropriate replacement.
Steel fire exit doors can be manufactured in single and double-door configurations. The correct arrangement will depend on the structural opening, required escape width, expected use and project specification.
Vision panels can be incorporated where appropriate for the doorset and application. The size, position and glazing specification should be agreed as part of the overall door design.

Related Doors

Get A Quote

Contact Information
Project Information
Uploads & Notes